Increased accuracy for low strength applications
DY-206 Automated pull-off tester ideally suited for low strength applications
DY-206 Automated pull-off tester ideally suited for low strength applications
DY-206 Automated pull-off tester ideally suited for low strength applications
DY-206 Automated pull-off tester ideally suited for low strength applications
DY-206
DY-206
DY-206
DY-206

Pull-off Testers

DY-206

Automated pull-off tester ideally suited for low strength applications

  • Reliable calibration accuracy
  • A comprehensive range of test discs
  • Easy to operate and program
Increased accuracy for low strength applications with a maximum pulling force of 6 kN
https://media.screeningeagle.com/asset/media/Brand/New%20Web%20Icons/Web%20Icons_21-10-20_Accuracy.svg
Accuracy
The ideal calibration accuracy EN ISO 7500-1 Class 2 for low strength applications such as testing adhesive strength of mortars and renders
https://media.screeningeagle.com/asset/media/Brand/New%20Web%20Icons/Web%20Icons_21-10-20_Performance.svg
Performance
A comprehensive range of test discs plus adjustable foot configuration to cover a wide variety of applications with complete reporting
https://media.screeningeagle.com/asset/media/Brand/New%20Web%20Icons/Web%20Icons_21-10-20_Ease%20of%20Use.svg
Ease of use
Easy to operate, even on overhead walls to add to a simple programming process of key parameters and a fully automated test

SWISS MADE_horizontal lockup.svg
DY-206 Tech Specs
Instrument
Tech Specs
Working Range
0.3 to 3.1 MPa (44 to 443 psi)

Tensile force (50 mm test disc)
0.6 to 6 kN (135 to 1349 Ibf)

Maximum Stroke
5 mm

Maximum Pulling Speed
4.65 mm/min (0.183 inch/min)

Instrument Firmware
Maximum load
Actual load rate
Test duration
Complete report of the test
Failure mode reporting
Full data review on instrument

PC Software
DY-2 Link with a live view of actual load rate graph

Memory
100 measurements

Connections
USB to PC and for charging

Calibration Accuracy
EN ISO 7500-1 Class 2 (±2 % from 20 % of the maximum force)

Battery Capacity
1500 mAh, 3.7V (min. 80 measurements)

Weight
4.5 kg

Applications:
✓Adhesive strength of mortars and renders
✓Adhesive strength of tiles
✓ Bond strength of coatings and overlays
✓ Tensile strength in concrete renovation
Standards & Guidelines

Standards

  • Arrow, click names to download Standards & Guidelines ASTM C 1583
  • Arrow, click names to download Standards & Guidelines ASTM C1857
  • Arrow, click names to download Standards & Guidelines ASTM D 4541
  • Arrow, click names to download Standards & Guidelines ASTM D 7234
  • Arrow, click names to download Standards & Guidelines ASTM D 7522
  • Arrow, click names to download Standards & Guidelines EN 1015-12
  • Arrow, click names to download Standards & Guidelines EN 12004-2
  • Arrow, click names to download Standards & Guidelines EN 1348
  • Arrow, click names to download Standards & Guidelines EN 1542
  • Arrow, click names to download Standards & Guidelines ISO 4624
  • Arrow, click names to download Standards & Guidelines JGJ 110
  • Arrow, click names to download Standards & Guidelines JGJ 126
  • Arrow, click names to download Standards & Guidelines JGJ 144
  • Arrow, click names to download Standards & Guidelines SIA 281/3
  • Arrow, click names to download Standards & Guidelines ZTV-ING
  • Arrow, click names to download Standards & Guidelines ГОСТ 22690
FAQ

What is the accuracy of the DY?

If correctly calibrated the DY is accurate to within 1% of the displayed load from the range 20% - 100% of the maximum load.
Below 20% maximal load, the 1% accuracy cannot be guaranteed, but results from the calibration...

See More

How is the DY calibrated?

The DY is calibrated according to methods defined in ISO EN 7500-1. It is not possible to calibrate the DY with static loads applied. Instead it is calibrated using a slowly increasing load. At the time of launch this...

See More

The DY does not always show 0.00 with no load applied. What can I do about this?

A small residual load may be displayed due to tolerances in the system. It is not possible to adjust this. This is irrelevant to the measurement accuracy provided it is within the defined limits. An acceptable value for...

See More